en

Teco TK-500 Chiller

The Teco TK-500 Tank Chiller, 1/6 HP, features an internationally-recognized high-end compressor and titanium coaxial heat exchanger for high performance, low energy consumption and low noise levels. A unique feature of this chiller is the integrated 400 watt heater. 

  • We can not ship a chiller expedited or to Hawaii, Alaska or Puerto Rico
  • User Manual
  • 1/6 HP
  • 9 degree cooling up to 120 gallons. Note: These temperature pull-down ratings are in ideal situations. We highly recommend purchasing a chiller one size larger than the specifications would lead you to believe is necessary.
  • Does not have a pump. The required flow through the chiller is between 106 gph and 211 gph.
  • Intuitive controller with extremely tight differential of 1°F. Displays in °F or °C, and audible alarms for certain situations.
  • Minimum Set Point 41°F. Maximum Set Point 95°.
  • Dimensions: 12.2" x 12.2" x 16.38"
  • 3/4" tube diameter In/Out Water Connection
  • Integrated 400 watt heater

EFFICIENT COOLING TECHNOLOGY

Internationally-recognized high-end compressors and titanium coaxial heat exchangers provide high performance, low energy consumption and low noise levels.

BUILT-IN HEATER

The TANK® TK-500 comes standard with a heater built into the unit (previously, had to be purchased and installed separately). The built-in heater provides better control over water temperatures and can be operated through the digital thermostat.

DIGITAL THERMOSTAT

Intuitive controller with accurate temperature detection from 32 to 95°F. Closed loop temperature control system with extremely tight differential of 1°F. Displays in °F or °C, and audible alarms for certain situations.

EFFICIENT DESIGN

Solid and durable structure designed to guarantee near perfect protection against corrosion. Rotatable in-set water connections, rotatable exhaust conveyor, and smaller form-factor helps facilitate placement of chiller in confined spaces.

Cooling Performance

Ability of the TANK TK-500 to pull down water temperatures in an 86°F room:

AQUARIUM SIZETEMP. ATTAINABLEHEATING LOADNET PULL-DOWNC.O.P.*
130 gallons77°F  from 86°F1.89 watts/gal.9°F cooler2.0
* Coefficient of Performance (COP) - a numerical value that represents cooling performance from a baseline room temperature of 86°F and a typical heat source (aka. Heating Load

 

$784.95 1/6hp